The HE 5721 valve controller unit is used to pulse solenoid valves in industrial dedusting technology.
The control unit implements numerous control and monitoring functions and can optionally be equipped with differential pressure measurement and control. Cleaning is time-controlled or differential pressure-dependent (with optional dp controller) with switching thresholds or pause time control. The 12 valves are monitored for overcurrent (short circuit) and interruption. With an extension unit, up to 24 valves can be controlled and mechanical valve function monitoring with a pressure switch is available as an option.
The HE 5721 valve control unit is suitable for use in explosion zone 22. For safe connection, we recommend the ATEX connection set # 57210088 incl. Multiple density inserts.
Setting options for the HE 5721 valve control unit
The time settings of the potentiometers have a logarithmic division
- Pulse time: 0.02 … 1.2 s
- Pause time: 1 … 270 s
- Number of valves: 1 … 12 valves (can be extended to 1 … 24 valves)
- Post-cleaning cycles: 0 … 12
- Post-cleaning start: 0 … 100% of the measuring range end value of the differential pressure measurement
Further setting options for the HE 5721 valve control unit
- “Cleaning stop” switching threshold
- “Cleaning start” switching threshold
- Alarm threshold
- dp zero point
Comprehensive technical data can be found in the respective operating instructions.